1.
Sci Total Environ ; 859(Pt 1): 160259, 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36402332

RESUMO

Horizontal flow wetlands have been designed using the so-called P-k-C* approach, which has been largely embraced by the treatment wetlands literature. P is meant to represent the equivalent number of apparent tanks in series (hydraulic factor), but also incorporates the loss of biodegradability as the wastewater undergoes treatment (kinetic factor). For design purposes, literature proposes fixed values of P. The proposal of this paper is to decouple hydraulics from kinetics and use the traditional concept of N or NTIS (number of tanks in series) as a function of geometric relationships of the wetland to be designed, leaving kinetic elements to be dealt with solely by the first-order removal rate coefficient (k). From the literature, a database with 41 wetlands with data from tracer studies was used, and a novel regression-based equation was derived relating N with the ratio length/depth of horizontal wetlands. This equation can be used at the design stage for estimating N and, hence, the output concentration of the pollutant using the traditional structure of the TIS model, with a possible inclusion of background concentration (C*). The paper presents all relevant equations, including those from the plug-flow with dispersion model (PFD), and it is shown how to convert from one hydraulic model to the other, what is also believed to be a novel approach in the treatment wetland literature. Finally, the area-based removal rate coefficients (kA) proposed by Kadlec and Wallace (2009) for designs of horizontal wetlands treating domestic wastewater based on the P-k-C* approach are converted into kA values for the TIS model in the paper.


Assuntos
Eliminação de Resíduos Líquidos , Áreas Alagadas , Águas Residuárias , Cinética
2.
Sci Total Environ ; 676: 333-342, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31048164

RESUMO

Identification of the degree of porous medium clogging in constructed wetlands (CWs) is a complex procedure because bed obstruction is a phenomenon that occurs in the subsurface and involves several factors. Ideal methods must allow for subsurface analysis and be non-invasive, what is the case of ground penetrating radar (GPR or georadar) used for soil characterization. Thus, this work aimed to evaluate the use of GPR for clogging characterization of two full-scale horizontal subsurface flow constructed wetlands (HSSF-CWs), one unit planted with cattail (Typha latifolia) and the other unit with no vegetation. Both units received municipal sewage (50 p.e. each) previously treated in an anaerobic reactor, had been in operation for seven years (at the time the GPR was used) and showed signs of heavy clogging, leading to surface flow. In order to produce a standard for GPR image (created by the response of the reflected wave in the passage through different media) identification and association of colors with the environmental conditions inside the medium (cleaner or more obstructed condition), a clean granular rock filter (in operation for only one month), similar to the unplanted unit, was used. Equations developed for indirectly estimating the porosity, based on the RGB (red, green and blue) color scale, indicated that the methodology was in agreement with the visual conditions of surface flow occurrence in the HSSF-CW, showing to be a suitable non-invasive method to characterize the advancement of clogging in CWs.

3.
Environ Technol ; 39(4): 490-502, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28271960

RESUMO

Post-treatment of anaerobic reactor effluent with maturation ponds is a good option for small to medium-sized communities in tropical climates. The treatment line investigated, operating in Brazil, with an equivalent capacity to treat domestic sewage from 250 inhabitants, comprised a upflow anaerobic sludge blanket reactor followed by two shallow maturation ponds (unbaffled and baffled) and a granular rock filter (decreasing grain size) in series, requiring an area of only 1.5 m2 inhabitant-1. With an overall hydraulic retention time of only 6.7 days, the performance was excellent for a natural treatment system. Based on over two years of continuous monitoring, median removal efficiencies were: biochemical oxygen demand = 93%, chemical oxygen demand = 79%, total suspended solids = 87%, ammonia = 43% and Escherichia coli = 6.1 log units. The final effluent complied with European discharge standards and WHO guidelines for some forms of irrigation, and appeared to be a suitable alternative for treating domestic sewage for small communities in warm areas, especially in developing countries.


Assuntos
Reatores Biológicos , Eliminação de Resíduos Líquidos/métodos , Amônia , Anaerobiose , Análise da Demanda Biológica de Oxigênio , Brasil , Filtração/métodos , Lagoas
4.
Water Sci Technol ; 76(2): 268-278, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28726693

RESUMO

Accumulated sludge in polishing (maturation) ponds reduces the hydraulic retention time (smaller useful volume), and this could potentially lead to a decrease in performance. However, settled biomass, present in the sediments, can contribute to nitrogen removal by different mechanisms such as nitrification and denitrification. This study investigated the influence of the bottom sludge present in a shallow maturation pond treating the effluent from an anaerobic reactor on the nitrification and denitrification processes. Nitrification and denitrification rates were determined in sediment cores by applying ammonia pulses. Environmental conditions in the medium were measured and bacteria detected and quantified by real-time polymerase chain reaction (real-time PCR). The pond showed daily cycles of mixing and stratification and most of the bacteria involved in nitrogen removal decreased in concentration from the upper to the lower part of the sludge layer. The results indicate that denitrifiers, nitrifiers and anammox bacteria coexisted in the sludge, and thus different metabolic pathways were involved in ammonium removal in the system. Therefore, the sediment contributed to nitrogen removal, even with a decrease in the hydraulic retention time in the pond due to the volume occupied by the sludge.


Assuntos
Nitrogênio/análise , Esgotos/química , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/análise , Reatores Biológicos , Brasil , Desnitrificação , Lagoas
5.
Water Sci Technol ; 72(4): 553-60, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26247753

RESUMO

This study presents a novel method for investigations on undisturbed samples from full-scale horizontal subsurface-flow constructed wetlands (HSSFCW). The planted fixed bed reactor (PFR), developed at the Helmholtz Center for Environmental Research (UFZ), is a universal test unit for planted soil filters that reproduces the operational conditions of a constructed wetland (CW) system in laboratory scale. The present research proposes modifications on the PFR original configuration in order to allow its operation in field conditions. A mobile device to obtain undisturbed samples from real-scale HSSFCW was also developed. The experimental setting is presented with two possible operational configurations. The first allows the removal and replacement of undisturbed samples in the CW bed for laboratory investigations, guaranteeing sample integrity with a mobile device. The second allows the continuous operation of the PFR and undisturbed samples as a fraction of the support media, reproducing the same environmental conditions outside the real-scale system. Investigations on the hydrodynamics of the adapted PFR were carried out with saline tracer tests, validating the proposed adaptation. Six adapted PFR units were installed next to full-scale HSSFCW beds and fed with interstitial liquid pumped from two regions of planted and unplanted support media. Fourteen points were monitored along the system, covering carbon fractions, nitrogen and sulfate. The results indicate the method as a promising tool for investigations on CW support media, rhizosphere and open space for studies on CW modeling, respirometry, kinetic parameters, microbial communities, redox potential and plant influence on HSSFCW.


Assuntos
Monitoramento Ambiental/métodos , Rizosfera , Poluentes Químicos da Água/análise , Áreas Alagadas , Reatores Biológicos , Brasil
6.
Water Sci Technol ; 71(6): 929-37, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25812104

RESUMO

Stabilization ponds are a highly appropriate system for treating sewage in small to medium size communities. However, sludge accumulation at the pond bottom occurs with the passage of time, reducing the net pond volume, which, in principle, could affect its performance. The objective of this paper is to compare the behaviour of two equal ponds in parallel treating the same flow of municipal wastewater from an upflow anaerobic sludge blanket reactor in Brazil. Each pond treated a population equivalent of around 125 inhabitants. One pond had approximately 40% of its net volume occupied by sludge after 11 years of operation, while the other pond had previously undergone complete desludging. The study covers the removal of biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (SS), nitrogen fractions and coliforms. Owing to the presence of a sludge layer, the theoretical hydraulic retention time (HRT) was lower in the pond without sludge. For BOD, COD, SS and Escherichia coli there were no significant differences (Wilcoxon matched-pairs test) between both ponds. The pond without sludge had significantly better removal efficiencies in terms of total Kjeldahl nitrogen and ammonia-N. The sludge layer probably allowed the occurrence of removal mechanisms that compensated for the reduction caused in the HRT.


Assuntos
Esgotos/análise , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/análise , Anaerobiose , Análise da Demanda Biológica de Oxigênio , Reatores Biológicos , Brasil , Cidades , Enterobacteriaceae/isolamento & purificação , Nitrogênio/análise , Lagoas
7.
Water Sci Technol ; 71(3): 329-37, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25714630

RESUMO

This paper presents a comparison between three simple sewage treatment lines involving natural processes: (a) upflow anaerobic sludge blanket (UASB) reactor-three maturation ponds in series-coarse rock filter; (b) UASB reactor-horizontal subsurface-flow constructed wetland; and (c) vertical-flow constructed wetlands treating raw sewage (first stage of the French system). The evaluation was based on several years of practical experience with three small full-scale plants receiving the same influent wastewater (population equivalents of 220, 60 and 100 inhabitants) in the city of Belo Horizonte, Brazil. The comparison included interpretation of concentrations and removal efficiencies based on monitoring data (organic matter, solids, nitrogen, phosphorus, coliforms and helminth eggs), together with an evaluation of practical aspects, such as land and volume requirements, sludge production and handling, plant management, clogging and others. Based on an integrated evaluation of all aspects involved, it is worth emphasizing that each system has its own specificities, and no generalization can be made on the best option. The overall conclusion is that the three lines are suitable for sewage treatment in small communities in warm-climate regions.


Assuntos
Reatores Biológicos , Esgotos , Eliminação de Resíduos Líquidos/métodos , Áreas Alagadas , Anaerobiose , Brasil , Filtração/métodos , Fósforo , Lagoas , Águas Residuárias
8.
Environ Technol ; 35(13-16): 2046-54, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24956799

RESUMO

This study aimed at assessing the influence of the return of excess aerobic sludge from a trickling filter (TF) upon the anaerobic digestion process in an upflow anaerobic sludge blanket (UASB) reactor, by evaluating its effect on the kinetics of the decay of specific organic matter (carbohydrates, proteins and lipids), as well as on the concentrations of volatile fatty acids in the UASB reactor. A pilot-scale UASB/TF system was used to perform the experiments, operating with (phase 2) and without (phase 1) excess sludge return from the TF to the UASB reactor. Sampling was carried out at different heights of the UASB reactor (0, 25, 125 and 225-cm height), and profile concentrations were determined for the following parameters: carbohydrates, proteins, lipids and volatile fatty acids. First-order kinetics showed the best fit to the decay of concentrations of carbohydrates, proteins, lipids and chemical oxygen demand (COD) in the UASB reactor. The parameters showing the best fit to the first-order kinetics were proteins and COD, during the sludge return phase. The occurrence of higher apparent reaction constants was further observed during the sludge return phase. For an influent COD concentration of 600 mg L-1 and hydraulic retention times of 2.1, 2.6 and 3.0 h in phase 1, the effluent COD concentrations were 125.3, 88.4 and 62.4 mg L-1, respectively, whereas in phase 2, the effluent COD concentrations were 75.5, 47.6 and 30.1 mg L-1, respectively.


Assuntos
Reatores Biológicos , Ácidos Graxos Voláteis/análise , Esgotos/química , Gerenciamento de Resíduos , Aerobiose , Análise da Demanda Biológica de Oxigênio , Biomassa , Cinética
9.
Water Sci Technol ; 68(7): 1599-606, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24135110

RESUMO

This study investigated the behaviour of two intermittently fed vertical flow constructed wetlands (one planted with Tifton 85 and the other unplanted) working in parallel, treating raw municipal sewage in Brazil for a population equivalent around 100 inhabitants. Based on a monitoring programme of over 2 years, the following items were evaluated: influence of batch frequency and the presence of Tifton 85 on the wetlands performance in terms of several physico-chemical and biological constituents. The unit with plants performed better than the one without, indicating a positive influence of the presence of plants. More attachment by total and volatile solids and larger amount of bacteria involved in the nitrogen cycle were observed in the planted filter medium, which can explain its higher nitrification and solids removal. The application of a smaller influent volume with a higher batch frequency improved the performance of both units. No signs of medium clogging have been observed in both units. The system simplicity and the good removal efficiency of organic matter, suspended solids, ammonia and helminth eggs indicate its high applicability in small communities in developing countries such as Brazil.


Assuntos
Esgotos , Eliminação de Resíduos Líquidos/métodos , Áreas Alagadas , Amônia , Animais , Bactérias/metabolismo , Brasil , Características da Família , Filtração , Helmintos , Nitritos , Óvulo , Oxirredução , Purificação da Água
10.
Water Sci Technol ; 67(12): 2746-52, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23787313

RESUMO

The objective of the work is to evaluate the performance of an innovative design of a trickling filter for small population sizes, which has been implemented for the post-treatment of sanitary effluent from a UASB (upflow anaerobic sludge blanket) reactor. The unit, named open trickling filter (OTF), operates with no side walls, no perforated bottom slab and no secondary settler. The OTF packing was 3.5 m high, composed of crushed stone, with a fixed distribution system made of channels with V-notch weirs. The OTF was operated with mean surface hydraulic loading rates of 4.1 and 9.3 m³ m⁻² d⁻¹, corresponding to population equivalents of approximately 250 and 550 inhabitants, respectively. For the surface hydraulic loading rate of 4.1 m³ m⁻² d⁻¹, the median removal efficiencies obtained by the OTF and overall system (UASB + OTF) were, respectively, 24 and 83% for total suspended solids (TSS), 44 and 79% for chemical oxygen demand (COD), 42 and 82% for biochemical oxygen demand (BOD), 40 and 40% for N-ammonia. For the surface hydraulic loading rate of 9.3 m³ m⁻² d⁻¹, the median removal efficiencies obtained by the OTF and global system (UASB + OTF) were 14 and 76% for TSS, 28 and 76% for COD, 25 and 86% for BOD, 15 and 15% for N-ammonia. Considering the great simplicity, no mechanization and small footprint of the system, these results can be considered satisfactory, suggesting that the OTF is suitable for small communities, especially in developing countries.


Assuntos
Cidades , Filtração/instrumentação , Amônia , Anaerobiose , Filtração/métodos , Eliminação de Resíduos Líquidos/métodos
11.
Water Sci Technol ; 65(2): 247-53, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22233902

RESUMO

The purpose of this research was to determine the feasibility of a UV photoreactor for the disinfection of effluent from a polishing pond following a UASB reactor treating domestic wastewater. For this, a 20 mm diameter photoreactor (20.7 litre volume) equipped with four 30 W submerged low-pressure mercury arc lamps was used. Three tests with contact times and doses ranging from 45 to 90 s and from 16.9 to 31.3 mW s cm(-2) were carried out. Inactivation of total coliforms and Escherichia coli varied from 2.6 to 3.4 log-units, even with the presence of suspended solids in the range of 87 to 102 mg L(-1). These results have shown that UV radiation disinfection of pond effluents can be a feasible alternative in areas with land restriction.


Assuntos
Desinfecção/métodos , Enterobacteriaceae/efeitos da radiação , Raios Ultravioleta , Eliminação de Resíduos Líquidos/métodos , Poluentes da Água/efeitos da radiação , Reatores Biológicos , Contagem de Colônia Microbiana , Enterobacteriaceae/isolamento & purificação , Escherichia coli/isolamento & purificação , Escherichia coli/efeitos da radiação , Tamanho da Partícula , Poluentes da Água/isolamento & purificação
12.
Water Sci Technol ; 65(4): 596-603, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22277217

RESUMO

This article presents an extensive study to select the theoretical probability distribution that represents the concentrations of major constituents from 35 wastewater treatment plants located in Brazil, as well as to verify the influence of the adopted treatment technology on the data distributions. Due to the lack of a solid basis for selecting the distributions that best fit the data, various distributions had to be tried and the choice was based on statistical tests and visual techniques, comprising a total of 3,444 tests undertaken. While comparing suitability of five distributions (normal, lognormal, gamma, exponential and rectangular) for analysis of data (influent and effluent biochemical oxygen demand, chemical oxygen demand, suspended solids, nitrogen, phosphorus, thermotolerant coliforms and flow), it was observed that the lognormal distribution was the most suitable, which is in agreement with the findings from other research studies. This conclusion requires a different position from the one currently adopted when analysing plant performance, in which symmetry of the data is generally implied, which has been shown not to be the case with the large array of data sets investigated.


Assuntos
Esgotos/química , Esgotos/microbiologia , Eliminação de Resíduos Líquidos/métodos , Purificação da Água/métodos , Brasil
13.
Water Sci Technol ; 64(7): 1428-34, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22179639

RESUMO

A sustainable option for nitrogen removal is the anaerobic ammonium-oxidizing (anammox) process in which ammonium is oxidized to nitrogen gas with nitrite as electron acceptor. Application of this process, however, is limited by the availability of anammox biomass. In this study, two Brocadia-like anammox phylotypes were successfully enriched, detected and identified from an activated sludge taken from a domestic wastewater treatment plant (Minas Gerais, Brazil) employing a Sequencing Batch Reactor (SBR). The dominant phylotype was closely related to 'Candidatus Brocadia sinica', but one clone seemed to represent a novel species for which we propose the name 'Candidatus Brocadia brasiliensis'. Based on Fluorescence in situ hybridization (FISH) analysis, this enrichment led to a relative population size of 52.7% (±15.6) anammox bacteria after 6 months of cultivation. The cultivation process can be divided into three phases: phase 1 (approximately 25 days) was characterized by heterotrophic denitrification metabolism, phase 2 was the propagation phase and phase 3 (from the 87th day onwards), in which significant anammox activity was detected. A long-term performance of the SBR showed a near perfect removal of nitrite based on the influent NO(2)(-)-N concentration of 61-95 mg L(-1). The average ammonia removal efficiency was 90% with the influent NH(4)(+)-N concentration of 55-82 mg L(-1). Therefore, anammox cultivation and enrichment from activated sludge was possible under a controlled environment within 3 months.


Assuntos
Amônia/metabolismo , Bactérias Anaeróbias/metabolismo , Esgotos/microbiologia , Anaerobiose , Biomassa , Reatores Biológicos , Hibridização in Situ Fluorescente , Filogenia
14.
Water Sci Technol ; 64(5): 1056-63, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22214051

RESUMO

The aim of this research was to assess the hydraulic behaviour of three intermittently-fed vertical flow wetland units operated in parallel, designed for the treatment of raw wastewater generated in the city of Belo Horizonte, Brazil. The system was designed to serve 100 PE (-1 m2/PE). The first filter was planted with cattail (Typha latifolia), the second with Tifton-85 (Cynodon spp.) and the third was maintained without plants (control unit). NaCl tracer tests were conducted to determine the residence time distribution. The tests were done with water when the system was unused (clean media) and also after an 11-month operation period with wastewater (used media), using two different dosing regimes (lower and higher frequency). Results showed a strong tendency towards the hydraulic completely mixed regime. A great dispersion in the units and the presence of short circuiting and dead zones were observed. The unsaturated condition in a large volume of the filter, even during the draining stage, was confirmed for the three units. The dosing regime, the resting period duration, the age of the filter and the presence of plants were found to influence the hydraulic processes in the units.


Assuntos
Purificação da Água/métodos , Áreas Alagadas
15.
Water Sci Technol ; 61(5): 1201-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20220242

RESUMO

This paper presents the results of a comparison of the performance of two treatment systems operating in parallel, with the same influent wastewater. The investigated systems are (i) UASB + three polishing ponds in series + coarse filter (200 population equivalents) and (ii) UASB + subsurface flow constructed wetlands (50 population equivalents). Two wetland units, operating in parallel, were analysed, being one planted (Typha latifolia) and the other unplanted. The systems were located in Belo Horizonte, Brazil. The wetland systems showed to be more efficient in the removal of organic matter and suspended solids, leading to good effluent BOD and COD concentrations and excellent SS concentrations. The planted wetland performed better than the unplanted unit, but the latter was also able to provide a good effluent quality. The polishing pond system was more efficient in the removal of nitrogen (ammonia) and coliforms (E. coli). Land requirements and cost considerations are presented.


Assuntos
Reatores Biológicos , Eliminação de Resíduos Líquidos/métodos , Purificação da Água/métodos , Amônia/química , Biodegradação Ambiental , Brasil , Cidades , Desenho de Equipamento , Filtração , Água Doce , Nitratos/química , Typhaceae/metabolismo , Poluentes Químicos da Água/isolamento & purificação , Abastecimento de Água , Áreas Alagadas
16.
Water Sci Technol ; 61(3): 737-43, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20150711

RESUMO

This work applied PCR amplification method and Fluorescence in situ hybridisation (FISH) with primers and probes specific for the anammox organisms and aerobic ammonia-oxidising beta-Proteobacteria in order to detect these groups in different samples from a wastewater treatment system comprised by UASB reactor and three polishing (maturation) ponds in series. Seven primer pairs were used in order to detect Anammox bacteria. Positive results were obtained with three of them, suggesting that Anammox could be present in polishing pond sediments. However, Anammox bacteria were not detected by FISH, indicating that they were not present in sediment samples, or they could be present but below FISH detection limit. Aerobic ammonia- and nitrite-oxidising bacteria were verified in water column samples through Most Probable Number (MPN) analysis, but they were not detected in sediment samples by FISH. Ammonia removal efficiencies occurred systematically along the ponds (24, 32, and 34% for polishing pond 1, 2, and 3, respectively) but the major reaction responsible for this removal is still unclear. Some nitrification might have occurred in water samples because some nitrifying bacteria were present. Also Anammox reaction might have occurred because Anammox genes were detected in the sediments, but probably this reaction was too low to be noticed. It is important also to consider that some of the ammonia removal observed might be related to NH(3) stripping, associated with the pH increase resulting from the intensive photosynthetic activity in the ponds (mechanism under investigation). Therefore, it can be concluded that more than one mechanism (or reaction) might be involved in the ammonia removal in the polishing ponds investigated in this study.


Assuntos
Bactérias/metabolismo , Compostos de Amônio Quaternário/metabolismo , Eliminação de Resíduos Líquidos/métodos , Aerobiose , Anaerobiose , Bactérias/genética , Betaproteobacteria/genética , Betaproteobacteria/metabolismo , Reatores Biológicos , Primers do DNA , DNA Bacteriano/genética , DNA Bacteriano/isolamento & purificação , Desenho de Equipamento , Amplificação de Genes , Oxirredução , Reação em Cadeia da Polimerase , Probabilidade , Compostos de Amônio Quaternário/isolamento & purificação , Eliminação de Resíduos Líquidos/instrumentação
17.
Water Sci Technol ; 61(3): 813-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20150719

RESUMO

Molecular techniques have been commonly used to detect and quantify pathogenic bacteria in food, clinical and environmental samples, but in wastewater treatment plants few studies have been carried out. This work applied PCR with a specific set of primers to investigate pathogenic bacteria in a wastewater plant comprised of a UASB reactor followed by polishing ponds. In addition, in-situ hybridisation technique (FISH) was used to estimate the abundance of Escherichia coli in the system. According to the PCR results it was observed that Escherichia coli and Salmonella enterica subsp. enterica were not completely removed in the system, since they were detected either in the raw sewage or UASB and pond effluents. Shigella dysenteriae and Enterococcus spp. were detected in raw sewage and UASB, but not in the pond effluent. In contrast Staphylococcus aureus and Helicobacter pylori were not detected in any samples. The quantification of E. coli using FISH revealed values in the range of 10(7) cells/100 mL for raw sewage and 10(6) cells/100 mL for pond effluent, slightly higher than values obtained by traditional techniques. Finally the results show the applicability of PCR method for monitoring pathogenic bacteria in wastewater systems; however, more samples need to be analysed in order to certify the applicability of FISH to estimate pathogenic bacteria in WWT effluents.


Assuntos
Escherichia coli/genética , Salmonella enterica/genética , Esgotos/microbiologia , Eliminação de Resíduos Líquidos/métodos , Purificação da Água/métodos , Reatores Biológicos , Enterococcus/genética , Enterococcus/isolamento & purificação , Enterococcus/patogenicidade , Escherichia coli/isolamento & purificação , Amplificação de Genes , Hibridização In Situ , Hibridização in Situ Fluorescente , Reação em Cadeia da Polimerase/métodos , Salmonella enterica/isolamento & purificação , Salmonella enterica/patogenicidade , Shigella dysenteriae/genética , Shigella dysenteriae/isolamento & purificação , Shigella dysenteriae/patogenicidade , Staphylococcus aureus/genética , Staphylococcus aureus/isolamento & purificação
18.
Arq. bras. med. vet. zootec ; 61(6): 1428-1433, dez. 2009. ilus, tab
Artigo em Português | LILACS | ID: lil-537271

RESUMO

Avaliou-se o desempenho de uma lagoa de polimento, no tratamento de efluentes de águas residuárias de suinocultura de um reator anaeróbio de manta de lodo (UASB). O sistema foi composto de decantador, reator UASB, em escala real, e lagoa de polimento em escala experimental. As análises físico-químicas realizadas foram: temperatura, pH, demanda bioquímica de oxigênio (DBO), demanda química de oxigênio (DQO), sólidos suspensos totais (SST) e sólidos suspensos voláteis (SSV), nitrogênio total kjedhal (NTK), nitrogênio amoniacal (N-am.) e orgânico (N-org.), fósforo total (Pt), coliformes totais e termotolerantes. A lagoa de polimento apresentou alto desempenho, com remoção média de 58,9 por cento de DBO, 60,1 por cento de NTK, 57 por cento de N-am. e 95,34 por cento de coliformes termotolerantes.


The performance of a polishing pond for treating swine wastewater from an upflow anaerobic sludge blanket (UASB) reactor was evaluated. The system was assembled with a slat settler, followed by an UASB reactor, on a real scale, and a post-treatment pond, on a demonstration scale. The following parameters were analyzed: temperature, pH, biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), volatile suspended solids (VSS), total Kjedahl nitrogen (NTK), ammonia nitrogen (N-am.), organic nitrogen, total phosphorus, and total and thermotolerant coliforms. The polishing pond was highly efficient, removing an average of 58.9 percent of BOD, 60.1 percent of NTK, 57 percent of N-am., and 95.34 percent of thermotolerant coliforms.


Assuntos
Lagoas de Maturação/efeitos adversos , Purificação da Água/métodos , Indústria Agropecuária/efeitos adversos , Matéria Orgânica , Reatores Anaeróbios de Fluxo Ascendente/prevenção & controle , Tratamento Aeróbio/métodos
19.
Water Sci Technol ; 59(7): 1299-306, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19380994

RESUMO

This article evaluates and compares the actual behavior of 18 UASB reactor systems operating without (10 plants) and with (8 plants) post treatment, considering their performance and their reliability in terms of compliance with specified discharge standards. The following types of post-treatment processes were analyzed: aerated filter; anaerobic filter; trickling filter; dissolved air flotation unit; facultative pond and maturation pond. The effluent quality and the removal efficiencies were compared with typical values reported in the technical literature. A methodology developed by Niku et al. (1979) was used for the determination of the coefficients of reliability, in terms of the compliance of effluent BOD and TSS with discharge standards. The results showed that, in general, the inclusion of a post-treatment step, be it either aerobic, anaerobic or physical-chemical, can provide a substantial improvement of the effluent quality from UASB reactors in terms of BOD and TSS. In terms of the systems reliability, the actual effluent concentrations from UASB reactor followed by some post-treatment processes would meet more restrictive discharge standards than those considered in this study (60 mg L(-1) for both constituents-values prevailing in most states in Brazil).


Assuntos
Reatores Biológicos , Eliminação de Resíduos Líquidos/métodos , Purificação da Água/métodos , Anaerobiose , Biodegradação Ambiental , Filtração , Resíduos Industriais , Eliminação de Resíduos Líquidos/normas
20.
Water Sci Technol ; 59(1): 15-22, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19151481

RESUMO

This article evaluates and compares the actual behavior of 166 full-scale anaerobic and aerobic wastewater treatment plants in operation in Brazil, providing information on the performance of the processes in terms of the quality of the generated effluent and the removal efficiency achieved. The observed results of effluent concentrations and removal efficiencies of the constituents BOD, COD, TSS (total suspended solids), TN (total nitrogen), TP (total phosphorus) and FC (faecal or thermotolerant coliforms) have been compared with the typical expected performance reported in the literature. The treatment technologies selected for study were: (a) predominantly anaerobic: (i) septic tank + anaerobic filter (ST + AF), (ii) UASB reactor without post-treatment (UASB) and (iii) UASB reactor followed by several post-treatment processes (UASB + POST); (b) predominantly aerobic: (iv) facultative pond (FP), (v) anaerobic pond followed by facultative pond (AP + FP) and (vi) activated sludge (AS). The results, confirmed by statistical tests, showed that, in general, the best performance was achieved by AS, but closely followed by UASB reactor, when operating with any kind of post-treatment. The effluent quality of the anaerobic processes ST + AF and UASB reactor without post-treatment was very similar to the one presented by facultative pond, a simpler aerobic process, regarding organic matter.


Assuntos
Eliminação de Resíduos Líquidos/métodos , Microbiologia da Água , Aerobiose , Anaerobiose , Reatores Biológicos , Brasil , Enterobacteriaceae/metabolismo , Fezes/microbiologia , Nitrogênio/isolamento & purificação , Nitrogênio/metabolismo , Compostos Orgânicos/isolamento & purificação , Compostos Orgânicos/metabolismo , Oxigênio/isolamento & purificação , Oxigênio/metabolismo , Fósforo/isolamento & purificação , Fósforo/metabolismo , Esgotos/química , Esgotos/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...